Level | MICS supported TimeTypes | Description |
---|---|---|
1. Minimal | 4. Effective | Minimum requirement is to provide a Time recording with only this timetype for a Task. The sum of all effective Time XML elements in a Task is the total working time of that Task. |
2. Intermediate | 2. Preliminary 4. Effective 5. Ineffective 6. Repair 7. Clearing 8. Powered Down | Detection of main work allows for automatic recording of timetypes 2, 4, 5, and 7. The detection of main work may use work status information from the devices allocated to a Task. Timetype 6 may require operator entry and timetype 8 may be recorded automatically based upon information broadcasted on the implement bus. |
Time - TIM Use Cases
PT9 Conformance Test Rules on interpreting TIM elements
...
Looking at the real life samples samples shows that there is no solution that would extract the best duration and DataLogValues in any situation. We tried to optimize for 'minimize error', 'simplicity of implementation' and 'reproducable, testable behavior'.
...
Use Case Type | Use Case Detail | ISO Implementation | ADAPT Type | ADAPT Implementation |
---|---|---|---|---|
TIM - planned | ||||